Initial
[Pr. ]
Name
Value
Auto tuning setting/
96
status
450 Second applied motor
453 Second motor capacity
Number of second
454
motor poles
Second motor
455
excitation current
Rated second motor
456
voltage
400V
Rated second motor
457
60Hz
frequency
Second motor constant
458
(R1)
Second motor constant
459
(R2)
Second motor constant
460
(L1)
Second motor constant
461
(L2)
Second motor constant
462
(X)
Second motor auto
463
tuning setting/status
Tuning data unit
684
switchover
859 Torque current
Second motor torque
860
current
Setting Range
0
0
1
101
0 to 8, 13 to 18, 20, 23, 24, 30, 33,
9999
34, 40, 43, 44, 50, 53, 54
9999
55K or less
0.4 to 55kW
9999
75K or more
0 to 3600kW
9999
2, 4, 6, 8, 10
9999
9999
55K or less
0 to 500A
75K or more
0 to 3600A
9999
9999
200/
0 to 1000V
*
10 to 120Hz
55K or less
0 to 50
9999
75K or more
0 to 400m , 9999
55K or less
0 to 50
9999
75K or more
0 to 400m , 9999
0 to 50
(0 to 1000mH),
55K or less
9999
9999
0 to 3600m
75K or more
9999
55K or less 0 to 50 (0 to 1000mH), 9999
9999
0 to 3600m (0 to 400mH),
75K or more
9999
55K or less 0 to 500 (0 to 100%), 9999
9999
75K or more 0 to 100 (0 to 100%), 9999
0
0
1
101
0
0
1
55K or less
0 to 500A
75K or more
0 to 3600A
9999
9999
55K or less
0 to 500A
75K or more
0 to 3600A
9999
9999
Offline auto tuning is not performed
Offline auto tuning is performed without motor running
Offline auto tuning is performed with motor running
Set when using the second motor.
(same specifications as [Pr. 71] )
Not function
Set the capacity of the second motor.
V/F control
Set the number of poles of the second motor.
V/F control
Tuning data of the second motor
(The value measured by offline auto tuning is automatically set.)
Uses the Mitsubishi motor (SF-JR, SF-HR, SF-JRCA, SF-
HRCA) constants
Set the rated voltage (V) of the second motor.
The initial value differs according to the voltage class. (200V/
400V)
Set the rated motor frequency (Hz) of the second motor.
,
9999
,
9999
Tuning data
(The value measured by offline auto tuning is automatically set.)
(0 to 400mH),
9999: Uses the Mitsubishi motor (SF-JR, SF-HR, SF-JRCA,
SF-HRCA, SF-V5RU(1500r/min series)) constants
Second motor auto tuning is not performed
Offline auto tuning is performed without second motor running
Offline auto tuning is performed with second motor running
Internal data converted value
Displayed in "A,
, mH, %".
Tuning data
(The value measured by offline auto tuning is automatically set.)
Uses the Mitsubishi motor (SF-JR, SF-HR, SF-JRCA, SF-HRCA,
SF-V5RU(1500r/min series)) constants
Tuning data of the second motor
(The value measured by offline auto tuning is automatically set.)
Uses the Mitsubishi motor (SF-JR, SF-HR, SF-JRCA, SF-HRCA,
SF-V5RU(1500r/min series)) constants