*10 These are not available for
*11 Increment is 1 when [ Pr. 37 =1 to 9998] or [ Pr. 144 =2 to 10, 102 to 110] in
Increment is 1 when [ Pr. 37 =0.01 to 9998] in
Parameter
[Pr.]
Register
41000 to
Refer to the parameter list (page 120) for the
0 to 999
parameter names.
41999
C2 (902)
41902
Terminal 2 frequency setting bias (frequency)
42092
Terminal 2 frequency setting bias (analog value)
C3 (902)
Terminal 2 frequency setting bias (terminal
43902
analog value)
125 (903)
41903
Terminal 2 frequency setting gain (frequency)
42093
Terminal 2 frequency setting gain (analog value)
C4 (903)
Terminal 2 frequency setting gain (terminal
43903
analog value)
C5 (904)
41904
Terminal 4 frequency setting bias (frequency)
42094
Terminal 4 frequency setting bias (analog value)
C6 (904)
Terminal 4 frequency setting bias (terminal
43904
analog value)
126 (905)
41905
Terminal 4 frequency setting gain (frequency)
42095
Terminal 4 frequency setting gain (analog value)
C7 (905)
Terminal 4 frequency setting gain (terminal
43905
analog value)
C12 (917)
41917
Terminal 1 bias frequency (speed)
*1
42107
Terminal 1 bias (speed)
C13 (917)
*1
Terminal 1 bias (speed) (terminal analog value)
43917
C14 (918)
41918
Terminal 1 gain frequency (speed)
*1
42108
Terminal 1 gain (speed)
C15 (918)
*1
Terminal 1 gain (speed) (terminal analog value)
43918
C16 (919)
41919
Terminal 1 bias command (torque/magnetic flux)
*1
42109
Terminal 1 bias (torque/magnetic flux)
C17(919)
*1
Terminal 1 bias (torque/magnetic flux) (terminal
43919
analog value)
C18 (920)
41920
Terminal 1 gain command (torque/magnetic flux)
*1
42110
Terminal 1 gain (torque/magnetic flux)
C19 (920)
*1
Terminal 1 gain (torque/magnetic flux) (terminal
43920
analog value)
C38 (932)
41932
Terminal 4 bias command (torque/magnetic flux)
*1
Terminal 4 bias (torque/magnetic flux)
42122
C39 (932)
*1
Terminal 4 bias (torque/magnetic flux) (terminal
43932
analog value)
C40 (933)
41933
Terminal 4 gain command (torque/magnetic flux)
*1
Terminal 4 gain (torque/magnetic flux)
42123
C41 (933)
*1
Terminal 4 gain (torque/magnetic flux) (terminal
43933
analog value)
*1
These are not available for
*2
These are not available for
.
D700
E700
D700
Parameter Name
.
F700
E700
D700
.
A700
F700
A700
F700
.
Read/Write
The parameter number + 41000 is the register
Read/write
number.
Read/write
Read/write
Analog value (%) set to [C3 (902)] is read.
Analog value (%) of the voltage (current) applied to
Read
the terminal 2 is read.
Read/write
Read/write
Analog value (%) set to [C4 (903)] is read.
Analog value (%) of the voltage (current) applied to
Read
the terminal 2 is read.
Read/write
Read/write
Analog value (%) set to [C6 (904)] is read.
Analog value (%) of the current (voltage) applied to
Read
terminal 4 is read.
Read/write
Read/write
Analog value (%) set to [C7 (905)] is read.
Analog value (%) of the current (voltage) applied to
Read
terminal 4 is read.
Read/write
Read/write
Analog value (%) set to [C13 (917)] is read.
Analog value (%) of the voltage applied to terminal
Read
1 is read.
Read/write
Read/write
Analog value (%) set to [C15 (Pr. 918)] is read.
Analog value (%) of the voltage applied to terminal
Read
1 is read.
Read/write
Read/write
Analog value (%) set to [C17 (Pr. 919)] is read.
Analog value (%) of the voltage applied to terminal
Read
1 is read.
Read/write
Read/write
Analog value (%) set to [C19 (Pr. 920)] is read.
Analog value (%) of the voltage applied to terminal
Read
1 is read.
Read/write
Read/write
Analog value (%) set to [C39 (Pr. 932)] is read.
Analog value (%) of the current (voltage) applied to
Read
the terminal 4 is read.
Read/write
Read/write
Analog value (%) set to [C41 (Pr. 933)] is read.
Analog value (%) of the current (voltage) applied to
Read
the terminal 4 is read.
470
PARAMETER
.
Remarks