2)
E700 D700
You can select the function that switches between
forward rotation and reverse rotation according to the
analog input terminal specifications and input signal.
For the terminal 2 for analog voltage input, 0 to 5V
(initial value) or 0 to 10V can be selected.
Either voltage input (0 to 5V, 0 to 10V) or current
input (4 to 20mA initial value) can be selected for
terminal 4 used for analog input.
Change the input specifications to change [Pr. 267]
and voltage/current input switch.
[Pr.]
Name
Analog input
73
selection
Terminal 4 input
267
selection
[Pr.73 ]
Terminal 2
Setting
Input
0
0 to 10V
1
0 to 5V
(initial value)
10
0 to 10V
11
0 to 5V
0
1
-
(initial value)
10
-
11
(
indicates main speed setting)
When [Pr. 561 PTC thermistor protection level ≠ 9999] in
Initial
Setting
Value
Range
0
Terminal 2 input 0 to 10V
1
Terminal 2 input 0 to 5V
1
10
Terminal 2 input 0 to 10V
11
Terminal 2 input 0 to 5V
Voltage/current input switch
0
Switch: I
0
1
Switch: V
2
Terminal 4 Input
AU signal
OFF
According to the [Pr. 267 ] setting
0: 4 to 20mA (initial value)
ON
1: 0 to 5V
2: 0 to 10V
D700
219
Current input (initial setting)
Voltage input
E700
Current input (initial setting)
Voltage input
D700
Description
Without reversible operation
With reversible operation
Terminal 4 input 4 to 20mA
Terminal 4 input 0 to 5V
Terminal 4 input 0 to 10V
Reversible
Operation
Not function
-
Not function
, terminal 2 does not function as analog frequency command.
PARAMETER
Control circuit terminal block
Description
Yes
Yes
2