[Pr. 71 (Pr. 450)] Setting
Thermal Characteristic of the Electronic Thermal Relay
*3
*4
[Pr. 71]
[Pr. 450]
4
Standard motor
Constant-torque motor
14
Vector control dedicated motor
SF-V5RU (except for 1500 r/min series).
Mitsubishi standard motor
24
(SF-JR 4P 1.5kW or less)
Vector control dedicated motor
34
(SF-V5RU (1500r/min series), SF-THY)
44
Mitsubishi high efficiency motor (SF-HR)
54
Mitsubishi constant-torque motor (SF-HRCA)
5
Standard motor
15
Constant-torque motor
6
Standard motor
16
Constant-torque motor
7
Standard motor
17
Constant-torque motor
8
Standard motor
18
Constant-torque motor
9999
—
Without second applied motor
(initial value)
*1
Motor constants of Mitsubishi high efficiency motor SF-HR
*2
Motor constants of Mitsubishi constant-torque motor SF-HRCA.
*3
Setting values for [Pr. 71] and [Pr. 450] differ by the model. Refer to the setting range in the table above for the setting values.
*4
[Pr. 450] is not available for
Function
Star
connection
Delta
connection
Star
connection
Delta
connection
.
F700
Standard
(SF-JR, etc.)
Auto tuning data can be
read, changed, and set.
Direct input of
motor constants
is enabled
Motor constants
direct input
+
offline auto tuning
267
PARAMETER
Motor ( : Used Motor)
Constant-torque
Vector
(SF-JRCA, etc.)
(SF-V5RU)
*1
*2
2