[Pr.]
Name
28
Multi-speed input compensation selection
0, 1
29
Acceleration/deceleration pattern selection 0, 1, 2, 3
30
Regenerative function selection
0, 2/0, 1, 2
31
Frequency jump 1A
0 to 400Hz, 9999
32
Frequency jump 1B
0 to 400Hz, 9999
33
Frequency jump 2A
0 to 400Hz, 9999
34
Frequency jump 2B
0 to 400Hz, 9999
35
Frequency jump 3A
0 to 400Hz, 9999
36
Frequency jump 3B
0 to 400Hz, 9999
37
Speed display
0, 1 to 9998
41
Up-to-frequency sensitivity
0 to 100%
42
Output frequency detection
0 to 400Hz
Output frequency detection for reverse
43
0 to 400Hz, 9999
rotation
44
Second acceleration/deceleration time
0 to 3600/360s
45
Second deceleration time
0 to 3600/360s, 9999
46
Second torque boost
0 to 30%, 9999
47
Second V/F (base frequency)
0 to 400Hz, 9999
48
Second stall prevention operation current
0 to 150%
Second stall prevention operation
49
0 to 400Hz, 9999
frequency
50
Second output frequency detection
0 to 400Hz
0 to 500A, 9999/
51
Second electronic thermal O/L relay
0 to 3600A, 9999
0, 5, 6, 8 to 14, 17, 20, 23 to
52
DU/PU main display data selection
25, 50 to 57, 100
1 to 3, 5, 6, 8 to 14, 17, 18,
54
FM terminal function selection
21, 24, 50, 52, 53
55
Frequency monitoring reference
0 to 400Hz
56
Current monitoring reference
0 to 500/0 to 3600A
0, 0.1 to 5s, 9999/
57
Restart coasting time
0, 0.1 to 30s, 9999
58
Restart cushion time
0 to 60s
59
Remote function selection
0, 1, 2, 3
60 Energy saving control selection
0, 4, 9
65
Retry selection
0 to 5
Stall prevention operation reduction starting
66
0 to 400Hz
frequency
67
Number of retries at fault occurrence
0 to 10, 101 to 110
68
Retry waiting time
0 to 10s
69
Retry count display erase
0
70
Special regenerative brake duty
0 to 10%
*5
71
Applied motor
0, 1, 2, 20
72
PWM frequency selection
0 to 15/0 to 6, 25
73
Analog input selection
0 to 7, 10 to 17
74
Input filter time constant
0 to 8
Reset selection/disconnected PU detection/
75
0 to 3, 14 to 17
PU stop selection
76
Fault code output selection
0, 1, 2
77
Parameter write selection
0, 1, 2
78
Reverse rotation prevention selection
0, 1, 2
79 Operation mode selection
0, 1, 2, 3, 4, 6, 7
Motor capacity (simple magnetic flux vector
0.4 to 55kW, 9999/
80
control)
0 to 3600kW, 9999
0 to 50Ω, 9999/
90
Motor constant (R1)
0 to 400mΩ, 9999
PARAMETER
Minimum Setting
Setting Range
Initial value Reference
Increments
1
0
1
0
1
0
*2
0.01Hz
9999
0.01Hz
9999
0.01Hz
9999
0.01Hz
9999
0.01Hz
9999
0.01Hz
9999
1
0
0.1%
10%
0.01Hz
6Hz
0.01Hz
9999
0.1/0.01s
5s
0.1/0.01s
9999
0.1%
9999
0.01Hz
9999
0.1%
120%
0.01Hz
0Hz
0.01Hz
30Hz
0.01/0.1A
9999
*2
*2
1
0
1
1
0.01Hz
60Hz
Rated inverter
0.01/0.1A
*2
*2
current
0.1s
9999
367, 416
*2
0.1s
1s
367, 416
1
0
1
0
1
0
0.01Hz
60Hz
1
0
0.1s
1s
1
0
0.1%
0%
1
0
1
2
*2
1
1
1
1
1
14
1
0
1
0
1
0
209, 434
1
0
252, 256
0.01/0.1kW
9999
*2
*2
0.001Ω/
9999
0.01mΩ
*2
*2
154
[Pr.]
Option
227
28
238
29
331
30
233
31
233
32
233
33
233
34
233
35
233
36
343
37
70
41
70
42
70
43
234
44
234
45
244
46
244
47
335
48
335
49
70
50
379
51
345
52
345
54
352
55
352
56
57
58
226
59
250
60
376
65
335
66
376
67
376
68
376
69
331
70
266
71
430
72
217
73
217
74
382
75
378
76
384
77
385
78
79
80
256
90
Control Mode-based
Instruction Code
Correspondence Table
Simple
Parameter
V/F
magnetic
Copy
Read
Write Extended
control
flux vector
control
1C
9C
0
1D
9D
0
1E
9E
0
1F
9F
0
20
A0
0
21
A1
0
22
A2
0
23
A3
0
24
A4
0
25
A5
0
29
A9
0
2A
AA
0
2B
AB
0
2C
AC
0
2D
AD
0
2E
AE
0
×
×
2F
AF
0
30
B0
0
31
B1
0
32
B2
0
33
B3
0
34
B4
0
36
B6
0
37
B7
0
38
B8
0
39
B9
0
3A
BA
0
3B
BB
0
3C
BC
0
×
41
C1
0
42
C2
0
43
C3
0
44
C4
0
45
C5
0
46
C6
0
47
C7
0
48
C8
0
49
C9
0
4A
CA
0
4B
CB
0
4C
CC
0
4D
CD
0
*7
*7
4E
CE
0
4F
CF
0
*7
*7
×
50
D0
0
5A
DA
0
×
154
PARAMETER
Parameter
All Parameter
Clear
Clear
2
×
×
×
×

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e700Fr-d700Fr-f700

Table of Contents