2. General Description
A: CAUTION
CAUTION:
• Do not use the electrical test equipment on
the airbag system wiring harnesses and con-
nector circuits.
• Be careful not to damage the airbag system
wiring harness.
• While diagnostic items are being checked, do
not operate radios, portable telephones, etc.
which emit electromagnetic waves near or in-
side the vehicle.
NG
• When turning the ignition switch to ON or
OFF while diagnostic items are being checked,
do not allow keys with different ID codes close
to the ignition switch. If the ignition key is on a
key holder, remove it from the key holder be-
fore performing diagnoses.
NG
General Description
• When repeatedly turning the ignition switch
to ON or OFF while diagnostic items are being
checked, it should be switched in cycles of
"ON" for at least 5 seconds
8 seconds.
• If the engine fails to start with a registered ig-
nition key, detach the ignition key from ignition
switch and wait for approx. 1 second until secu-
rity indicator light begins to flash. And then
start the engine again.
IM-00211
• Before performing the diagnostics, obtain all
keys for the vehicle from the owner.
• Do not install or register a body integrated
unit already registered to another vehicle to di-
agnose failures or inspect functions.
IM-00212
IM(diag)-3
IMMOBILIZER (DIAGNOSTICS)
ON
(1)
OFF
5
8
(1) Ignition switch position
(2) Sec.
"OFF" for at least
(2)
IM-00003