Timing chart for image density control (Dmax & Dhalf)
Density detection control
sequence command
Sequence
Dmax & Dhalf initial rotation
1
2
ITB home position signal
3
Fixing motor (M2)
4
Drum Motor (M3)
5
Toner cartridge motor (M4)
6
Developing rotary motor (M5)
7
Primary charging bias (AC)
8
Primary charging bias (DC)
9
Developing bias (AC)
10
Developing bias (DC)
11
12
ITB unit contact clutch (CL2)
13
Toner level sensor
14
Scanner motor
15
Laser drive
16
17
18
Note: During Dmax & Dhalf control, the DC controller ignores the ITB home position signal and controls with the DC controller internal signal (Dummy TOP signal).