6.2 Connect the RTC Battery

The AIWS circuit board includes a 3V lithium battery which will keep the boards real time clock (RTC) running when power
to the AIWS is off. The AIWS is shipped with the battery disconnected. To connect the battery, locate the switch J1 at the
top right of the board. Move the switch jumper to position 2-3.

6.3 Cable Connections

1. Locate the switch sets SW2 and SW3 at the top-right of the AIWS circuit board. Ensure that all the switches are set
to Off.
2. Locate the LAN port and the J5 power connector. Just below these is a plastic panel. With care remove sufficient
parts of the panel to allow cable access to the LAN port and power connector when the AIWS cover is put back.
3. Connect the LAN cable from the IP Office to the AIWS.
4. Connect the power supply cable to the J5 power connector next to the AIWS LAN port.
5. Switch on power to the AIWS unit.
DECT R4
IP Office Release 7.0
AIWS Installation: Removing the AIWS Cover
15-601047 Issue 03a (21 February 2011)