AMAX panel 4000 / AMAX panel 4000
EN
Keypad User Codes #1 to #64 (reported 1 to 64)
Key Fob User Codes *1 to *128 (reported 65 to 192)
User Codes for special purpose:
Use User Code 254 to send report when arming/disarming the system by key-switch user.
Use User Code 253 to send report when arming the system in AWAY Mode or STAY Mode by
keypad single button.
Use User Code 252 to send report when remotely arming the system by telephone call.
Use User Code 251 to send report when remotely arming the system by A-Link Plus software.
User Code can be four to six digits long. Each User Code should get assignment to area(s) and
to an authority level.
7.5
System Settings - General
This chapter describes eight categories of system settings including the system date and time,
telephone settings, etc.
7.5.1
Installer Access Until Next Arming
Before using installer access, a standard user has to enable installer access first. If option
Installer Access Until Next Arming is enabled, installer access permission is limited to next
arming.
7.5.2
Force Arm When System Is In Trouble Condition
If option Force Arm When System Is In Trouble Condition is enabled, an area can be force
armed however there is trouble condition.
7.5.3
Siren / PO-1+PO-2 Supervision
If option is enabled, system supervises whether siren is shortened or disconnected.
7.5.4
Keypad 2 Button Alarm
If option Keypad 2 Button Alarm is enabled, the following alarms can be sent by pressing and
hold two keypad buttons simultaneously.
Emergency alarm will be transmitted, if simultaneously [1] and [3] or [*] and [#] is pressed
and hold.
Fire alarm will be transmitted, if simultaneously [4] and [6] is pressed and hold.
Silent keypad emergency medical alarm will be transmitted, if simultaneously [7] and [9] is
pressed and hold.
7.5.5
Phone Line Monitor
If option Phone Line Monitor is enabled, system supervises whether phone line is broken or
disconnected.
7.5.6
Beep For Warning Devices
Enables/disables Beep For Warning Devices when the system is armed, disarmed or during
Walk Test.
7.5.7
Silence Warning Device When Disarmed
Enables/disables Silence Warning Device when disarmed or by pressing any key.
Bosch Sicherheitsysteme GmbH
Installation Guide
Settings | en
65
2013.07 | 03 | F.01U.267.112