Configuration

A number of functions of the Plena Voice Alarm System is hardware configured using, for
example, DIP switches and volume controls. Other parts of the system must be software
configured using the Plena Voice Alarm System configuration software. A description of this
software is beyond the scope of this manual. This manual only describe the hardware
configuration of a Plena Voice Alarm System.
NOTICE!
See the Configuration Software Manual (9922 141 1038x) for more information about the
configuration software.
It is recommended to do the hardware configuration of the system before the software
configuration.
6.1

System settings

The system settings are configured using DIP switches on the rear of the voice alarm
controller (see Figure 6.1). By default, all switches are in the OFF position.
Figure 6.1 System settings DIP switches
No
1
2
3
4
5
Table 6.1 System settings DIP switches
6.1.1

Monitor

If the Monitor switch (see Figure 6.1) is in the ON position, the internal monitoring
loudspeaker of the voice alarm controller is switched on. The volume of the monitoring
loudspeaker is set with the Monitoring Speaker volume control (see Figure 3.2, no. 36).
6.1.2

APR mode

If the APR mode switch (see Figure 6.1) is in the ON position, the system is in the Asian-Pacific
Region (APR) mode. In APR mode, the system operates according to the emergency standards
of the Asian-Pacific Region. In the APR mode:
Bosch Security Systems B.V.
Off
On
DIP switch
Description
Monitor
Switches the monitoring loudspeaker on (ON) and off (OFF).
See section 6.1.1 .
APR mode
Switches the Asian Pacific Region mode on (ON) and off (OFF).
See section 6.1.2 .
Supervision
Switches supervision on (ON) and off (OFF).
See section 6.1.3 .
2ch operation
Switches2-channel operation on (ON) and off (OFF).
See section 6.1.4 and section 6.1.5 .
Reserved
Reserved. This DIP switch must always be in the OFF position.
The priority level of the emergency trigger inputs is always 14.
Emergency and business trigger inputs of the same zone form pairs. The settings of the
emergency trigger input (software configurable) apply to both.