Address Setting; Configuration; Status Indicator - Bosch AMAX panel 4000 Installation Manual

Icp-amax4-p1 / icp-amax4-p2-en / icp-amax-p3-en
Hide thumbs Also See for AMAX panel 4000:
Table of Contents

Advertisement

20
en | Optional Modules and Peripheral Devices
B426
Figure 5.10: Connecting B426 to the Control Panel
5.4.4

Address Setting

Turn the rotary switch to 6, i.e., set the address to 134 when the first B426 is used. Turn the
rotary switch to 9, i.e., set the address to 250 when the second B426 is used.
Notice!
When data bus address is changed, the module needs to be re-powered to make the new
address effective.
5.4.5

Configuration

To reconfigure the module or connected to the alarm control panel with RPS, the network or
direct connection must be used to access its built-in Web server.
For more information about configuration, see B426 Installation and Operating Guide.
5.4.6

Status Indicator

B426 provides the following on-board LED indicators to help in troubleshooting.
Refer to the Table below for details.
Color
Blue
Blue
Blue
Blue
Table 5.9: Functions of B426 System indicators
2013.07 | 03 | F.01U.267.112
Alarm Control Panel
Red
Yellow
Green
Black
Blue system status indicator.
Green data bus indicator.
Green Ethernet link indicator.
Flash Mode
Stable flash
3 flashes
Constant on
Constant off
Function
Normal operation.
Normal power supply, without communication.
Failure conditions.
Power interruption or other failure conditions.
Installation Guide
AMAX panel 4000 / AMAX panel 4000
Bosch Sicherheitsysteme GmbH
EN