Auxiliary Power Fault Report
When the system detects auxiliary power fault, the report will be sent.
Auxiliary Power Fault Restore Report
When the system detects auxiliary power fault recovery, the report will be sent.
AC Power Fault Report
When the system detects disconnection of AC power, the report will be sent.
AC Power Fault Recovery Report
When the system detects recovery of AC power, the report will be sent.
Battery Low Voltage Fault Report
When the battery voltage is lower than 11.0V or battery low voltage is detected in dynamic
battery test, the alarm control panel will send battery low voltage report.
The system continuously monitors the battery voltage and will perform a dynamic battery test
each time the system is armed, when the system is reset, or every 4 hours.
Battery Low Voltage Fault Recovery Report
When the battery voltage is lower than 12.0V or recovery to normal voltage is detected in
dynamic battery test, the battery low voltage fault recovery report will be sent.
Times of Wrong Code Entry Exceeding Limit
When the times of entering wrong code reach the specified one, an access denial report will
be generated and alarm will be made.
This function limits the times of malicious attempts of password by the unauthorized user.
When the times of entering wrong password reach the specified one by programming, the
alarm control panel will execute following actions:
On-board Output 1 – 2 Fault
When on-board output 1 or 2 fails, the report will be sent. When the on-board output resumes
to normal conditions, the programmable output fault recovery report will be sent.
Communication Path 1 - 4 Fault
When any communication paths fail, the report will be sent. When the communication
resumes to normal conditions, the communication fault recovery report will be sent.
Changing Programming Parameters
When the programming parameters are changed and take effect, the report will be sent.
Keypad Emergency Alarm Reporting
To press and hold both [1] and [3] for 3 seconds, or press and hold both [#] and [*] for 3
seconds, the emergency alarm report will be sent.
The emergency alarm report has not corresponding alarm recovery report.
Keypad Fire Alarm Reporting
To press and hold both [4] and [6] for 3 seconds, the fire alarm report will be sent.
The fire alarm report has not corresponding alarm recovery report.
Keypad Medical Aid Reporting
To press and hold both [7] and [9] for 3 seconds, the medical aid alarm report will be sent.
The medical aid alarm report has not corresponding alarm recovery report.
Automatic Test Reporting
The system supports sending automatic test report.
Bosch Sicherheitsysteme GmbH
Activate alarm siren and other alarm output.
Lock all keypads for 3 minutes.
Send access denial report.
Installation Guide
Settings | en
43
2013.07 | 03 | F.01U.267.112