en | Settings
0
If a zone is not used, program the zone type location to 0. An EOL resistor is not required if
this zone type is not used. This zone type never activates the sirens or the dialer.
1 - Instant
The instant zone will perform as below:
1.
2.
3.
2013.07 | 03 | F.01U.267.112
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
Disarm:
Zone normal - no Alarm / no report
Zone triggered - no Alarm / no report
AWAY Arm:
Zone normal - no Alarm / no report
Zone triggered - Alarm / report
(Zone triggered during exit time no Alarm / no report)
(Zone triggered during entry time Alarm / report is delayed for 30sec or entry time is
expired, when system is disarmed before, no report)
STAY Arm:
Zone normal - no Alarm / no report
Zone triggered - Alarm / report
(Zone triggered during exit time no Alarm / no report)
(Zone triggered during entry time Alarm / report is delayed for 30sec or entry time is
expired, when system is disarmed before, no report) When Zone is triggered, not
bypassed and system is forced to arm, a Zone fault report is sent.
When System is disarmed and zone is not restored before, a Zone fault restore
report is sent.
Follower
Interior Follower
24-Hour
Key-Switch Toggle
Key Switch on/off
24 Hour Panic
24 Hour Fire
24 Hour Fire With Verification
Tamper
Bolt Contact
External Fault
Delay Exit
Interior Delay Exit
Technical Alarm
Reset
Instant Without Reset
Reserved
Installation Guide
AMAX panel 4000 / AMAX panel 4000
Bosch Sicherheitsysteme GmbH
EN