Bosch AMAX panel 4000 Installation Manual page 75

Icp-amax4-p1 / icp-amax4-p2-en / icp-amax-p3-en
Hide thumbs Also See for AMAX panel 4000:
Table of Contents

Advertisement

AMAX panel 4000 / AMAX panel 4000
EN
3.
6 - Communication Failure
Condition:
Panel can not send the report to the Destination 1 after 4 attempts.
Restore:
The fault is reset when the first kissoff tone is received and fault is reset.
Supervise:
1.
2.
3.
7- Tamper
The zone indicator 7 lights to indicate Tamper conditions. Enter [7] to step to Tamper
conditions list for more information.
System Tamper
Onboard Tamper Condition is registered when the Onboard Tamper input (P8) is open.
Condition:
Onboard Panel Tamper input P8 is open.
Restore:
The Tamper condition is reset when the Input is shorted and Tamper condition is reset.
Supervise:
1.
2.
3.
Keypad Tamper
Condition:
Keypad 1 is opened and the Tamper contact is triggered.
Restore:
The Tamper condition is reset when the Keypad is closed and Tamper condition is reset.
Supervise:
1.
2.
3.
Zone Expansion Module Tamper
Zone extension module 1 to 6 tamper
When the disassembly of DX2010 module 1, 2, 3, 4, 5 or 6 is detected, zone extension module
1, 2 tamper report will be sent. When the module resumes to normal operation, the fault
recovery report will be generated.
Fault conditions:
When the disassembly of DX2010 module 1, 2, 3, 4, 5 or 6 is detected, the alarm control panel
will consider the occurrence of zone extension module 1, 2, 3, 4, 5 or 6 tamper.
Bosch Sicherheitsysteme GmbH
No report to the control panel system when date and time setting is recorded in
nonvolatile memory and Control Panel is reset. The FAULT indicator is turned off when
there is no other system fault.
Communication Fault 1 - 4
Report the fault to configured destination on address 124 when the fault is detected.
Slow flash FAULT indicator (refer the detailed description in chapter keypad indicators).
When the fault is reset, send the restored report to the configured destinations. The
FAULT indicator is turned off when there is no other system fault.
Report the Tamper condition to configured destination on Address 124 when the Tamper
Condition is detected.
Slow flash FAULT indicator (refer the detailed description in chapter keypad indicators).
When the Tamper Condition is reset, send the restored report to the configured
destinations.
Report the Tamper condition to configured destination on Address 124 when the Tamper
Condition is detected.
Slow flash FAULT indicator (refer the detailed description in chapter keypad indicators).
When the Tamper Condition is reset, send the restored report to the configured
destinations. The FAULT indicator is turned off when there is no other system fault.
Installation Guide
Settings | en
75
2013.07 | 03 | F.01U.267.112

Advertisement

Table of Contents
loading

Table of Contents