112
en | Programming
Zone Pulse Count Duration
Address 0198 - 0200
0 = Disable, 1-999sec = Duration
Event Record Count per Set/Unset Period
Address 0201
3 - 10
System Tamper Indication In Area
Address 0202
0 = Area 1, 1 = All Areas
Internal Siren Beep As Indication
Address 0203
0=Disable, 1=enabled
Battery Check Interval
Address 0204
0 = Disabled , 1-15 minutes
Cross Zone Timer
Address 0205 - 0207
001 - 999 sec
AC Power Supply Fault Report Delay
Address 0208 - 0209
99 = Disabled, 00 - 98 minutes
Domestic Telephone Number
Address 1618 - 1682
Domestic Telephone Number 1
Domestic Telephone Number 2
Domestic Telephone Number 3
2013.07 | 03 | F.01U.267.112
Installation Guide
AMAX panel 4000 / AMAX panel 4000
Address
Default
0198
060
VDS-A
EN=000
Address
Default
0201
10
EN=10
Address
Default
0202
0
Address
Default
0203
0
Address
Default
0204
15
VDS-A
EN=15
Address
Default
0205 - 0207
060
Address
Default
0208 - 0209
60
VDS-A
EN=00-60
Address
Default
1618 - 1633
15
1634 - 1649
15
1650 - 1665
15
Bosch Sicherheitsysteme GmbH