AMAX panel 4000 / AMAX panel 4000
EN
Panel PCB:
Battery:
Certification:
Keypads:
IUI-AMAX4-TEXT (LCD Text Keypad)
Relative Humidity:
Operating Temperature:
Input Voltage range:
Current Consumption:
Cable requirements:
EN type:
Certification:
IUI-AMAX3-LED16 (16 Zone LED Keypad)
Relative Humidity:
Operating Temperature:
Input Voltage range:
Current Consumption:
Cable requirements:
EN type:
Certification:
IUI-AMAX3-LED8 (8 Zone LED Keypad)
Relative Humidity:
Operating Temperature:
Input Voltage range:
Bosch Sicherheitsysteme GmbH
Quiescent current maximum 100mA
12V/7 Ah, lead acid rechargeable
12V/17Ah, lead acid rechargeable
Low battery condition is below 11,0 VDC
Minimum battery condition is 10,8VDC
EN 50131-3 Grade-3 Environmental Class-II
10%-95%
-10°C - +55°C
10.8VDC - 13.8VDC
standby 31mA
maximum 100mA
four wire, AWG18 or AWG22
maximum length 200m (Panel to last KP)
maximum BUS 1 length 700m (max 14 devices, max 8
KPs)
maximum BUS 2 length 700m (max 14 devices, max 8
KPs)
EN = B, IK = 06, IP = 30
EN 50131-3 Grade-3 Environmental Class-II
10%-95%
-10°C - +55°C
10.8VDC - 13.8VDC
standby 31mA
maximum 60mA
four wire, AWG18 or AWG22
maximum length 200m (Panel to last KP)
maximum BUS 1 length 700m (max 14 devices, 8 KPs)
maximum BUS 2 length 700m (max 14 devices, 8 KPs)
EN = B, IK = 06, IP = 30
EN 50131-3 Grade-3 Environmental Class-II
10%-95%
-10°C - +55°C
12V normal