When RPS is opened, a connection can only be established when the IP address and port
number of the alarm control panel have not changed, after RPS received previous data..
If the IP address has changed RPC with running RPS must wait for the next UDP Data package
send from the Panel.
Number of Rings
The address sets the number of rings of the alarm control panel before answering incoming
calls. Please set proper number of rings. This setting is only related to the connection of
remote programming software by means of telephone. Setting this address to 0 can disable
the alarm control panel to answer all incoming calls no matter how other programming
addresses are set.
Telephone Remote Connection
Use telephone to remotely program and control the system.
For telephone remote connection to enable programming, see Telephone Remote Connection.
Call back Telephone Number
This address stores the telephone number to call when Upload/Download is requested or the
user enters his code + [5][7] and presses [#] to initiate a modem call from the control panel
to establish a communication link with the remote computer. The computer must be running
A-Link Plus RPS software and must be set to Waiting for an Incoming Call. The Call Back
Telephone Number is also necessary if remote connect with call back verification is required.
Ring Count
This address sets the number of rings before the control panel answers an incoming call.
Setting this count to an acceptable level has an effect only if Remote Arming and the Remote
Upload/Download are enabled. Programming this address to 0 prevents the control panel from
answering incoming calls regardless of any other programmed options.
7.1.10

Domestic Call

Four dialing telephone numbers will be supported.
When the control panel is activated into zone tamper/ zone alarm, it dials the programmed
telephone number.
All alarm events only need one report/acknowledgement.
The transmission sequence is repeated until the control panel receives an acknowledgement
tone.
The control panel automatically hangs up after 45 seconds if it cannot detect the
acknowledgement tone. And redial later.
The user presses [#] between two acknowledgement tones to confirm the alarming.
The acknowledgement tone is the DTMF signal sent by the remote user with the [#] .
If the control panel got the [#] acknowledgement from the user, it will send 2 seconds long
beep as acknowledge tone and hang up the line.