Telephone Remote Arming
The user dials the control panel number. The control panel answers the call and issues a long
beep. After the long beep, the user must press the [#] key. When the Panel receives the signal
it will confirm the arming of the control panel with a high tone.
Please contact your installer to enable/disable this function.
Notice!
Telephone arming is possible when the system has only 1 assigned area.
Key Switch Arming
Users can use a key switch to Arm and Disarm the system. When the Key switch is activated,
the AWAY indicator flashes slow and exit time starts. After exit time, the AWAY indicator is lit.
When the Key switch is deactivated, the system is disarmed and Away indicator is off.
10.2.2

Disarming the System

Disarming with CODE
Enter your code and press [#] .It beeps twice and the AWAY or STAY indicator is extinguished.
Disarming with Key Switch
When the Key switch is deactivated, the system is disarmed and the AWAY or STAY indicator is
extinguished.
10.3

Faults and Tamper Conditions

Whenever a system fault or tamper condition occurs, the FAULT or MAINS indicator flashes
and the keypad beeps.
Notice!
Operation is only possible in disarmed status.
10.3.1

System Fault or Tamper Analysis Mode in LED Keypad

To enter fault or tamper analysis mode for determining a system fault or tamper condition:
a) Enter your Code + [2] [1] and press [#]. It beeps twice. The FAULT indicator remains lit and
the STAY and AWAY indicators flash. The lit zone indicators indicate the type of fault or tamper
condition that occurred.
b) For a multi-level menu, enter the corresponding number to enter the submenu, press [ 0 ]
key to return to the main menu (see table next page).
c) To exit from Fault and Tamper Analysis Mode, press [#]. The STAY and AWAY indicators are
extinguished and the FAULT indicator remains lit, and the keypad stops the beep.