10.3.2

System Fault or Tamper Analysis Mode in Text Keypad

To enter fault or tamper analysis mode for determining a system fault or tamper condition:
a) Enter your Code + [2] [1] and press [#]. It beeps twice.
b) Scroll down with [ arrow] to display all trouble or fault conditions.
Bosch Sicherheitsysteme GmbH
Output Failure
3
Onboard Output Failure
1
1 Onboard Output 1 Fault
2 Onboard Output 2 Fault
Keypad Failure
4
Keypad 1 – 16 Fault
System Failure
5
Date Time not set
1
Communication Failure
6
1 Communication Fault 1
2 Communication Fault 2
3 Communication Fault 3
4 Communication Fault 4
5 Phone Line Fault
7 Tamper
System Tamper
1
2
Keypad Tamper
1 - 16
Keypad 1 – 16 Tamper
3
Zone Expansion Module Tamper
1 - 6 Zone Expansion Module 1 - 6 Tamper
4
Zone Tamper DEOL
1 - 16
Sensor Tamper DEOL
5
Zone type Tamper
1 - 16
Zone type Tamper
6
Keypad Lock out
1 Keypad Lock out
7
RF Receiver Tamper
1 RF Receiver Tamper
8
RF Repeater Tamper
1 - 8 RF Repeater Tamper
External Failure
8
1 - 16
External Fault Zone 1-16
Installation Guide
Keypad Usage and Operations | en
2013.07 | 03 | F.01U.267.112