7.7.2

Area Delay

Exit Delay
As for the programming of exit delay, the programming rang is 0 - 255 seconds. In the mode of
system arming, the keypad will beep during exiting and will make continuous long beep in the
last 10 seconds to notify the exit time is coming to an end.
For programming of exit delay, see Exit Delay.
Entry Delay
As for the programming of entry delay, the programming rang is 0 - 255 seconds. Entry delay
id the delay time of the delay zone.
For programming of exit delay, see Entry Delay.
For more information about delay zone, see Delay zone.
7.7.3

Keypad Area

Master Keypad
The system supports up to 16 master keypads. The arming/disarming, area alarm, AC power
fault, system fault and system event of each area can be displayed on the master keypad. It is
not possible to execute arming/disarming and bypass operation on the master keypad. When
relevant operations are made to the area, the master keypad should be switched to the
corresponding area.
Area Keypad
It is possible to operate each area with a single or multiple independent keypads.
Each area keypad can only operate the corresponding area of the programming,
When the area keypad has not corresponding zones, the area keypad cannot be used to
execute zone-related operations such as arming/disarming and bypass, but can be used to
execute operations without relations to the zone, e.g. event inquiry.
Each area keypad can display the status of the zone belonging to the area. However, for IUI-
AMAX3-LED8 keypad, IUI-AMAX-LED8 keypad and IUI-AMAX-LCD8 keypad, each area can
display up to 8 zones and cannot display other zones, but can report zone events. For IUI-
AMAX3-LED16 keypad, each area can display up to 16 zones and cannot display other zones,
but can report zone events. The keypad can display up to 64 zones.
For any areas, the logic numbers of the zones are displayed on the LED/Icon LCD keypad and
logic numbers or zone names of the zones are displayed on the keypad instead of actual
physical numbers. For example: The zones 1, 2 and 3 of area 1 displayed on the keypad are
actually zones 20, 31 and 37.
For programming of keypad specified area, see Keypad Area Settings.
Bosch Sicherheitsysteme GmbH
If any zones under common zones are in triggered or tamper status and the forced arming
is disabled, the common area cannot be armed.