22. The addition or edit of the network pool's advanced settings requires the following
Boot File
BOOTP Next Server
Enable Unicast
23. Set the following
NetBIOS
NetBIOS Node Type
Figure 9-12 DHCP Pools screen - Advanced tab
Enter the name of the boot file used with this pool. Boot files (Boot Protocol) can be used
to boot remote systems over the network. BOOTP messages are encapsulated inside UDP
messages so requests and replies can be forwarded. Each pool can use a different file as
needed.
Provide the numerical IP address of the server providing BOOTP resources. Select Alias to
use a network alias with the BOOTP Next Server configuration. For more information see
Alias on page
7-34.
Unicast packets are sent from one location to another location (there's just one sender,
and one receiver). Select this option to forward unicast messages to just a single device
within the network pool. This setting is disabled by default.
parameters for the network pool:
Set the NetBIOS Node Type used with this pool. The following types are available:
Broadcast - Uses broadcasting to query nodes on the network for the owner of a NetBIOS
name.
• Peer-to-Peer - Uses directed calls to communicate with a known NetBIOS name server,
such as a WINS server, for the IP address of a NetBIOS machine.
• Mixed - Is a mixed node using broadcast queries to find a node, and failing that, queries
a known p-node name server for the address.
• Hybrid - Is a combination of two or more nodes.
• Undefined - No NetBIOS Node Type is used.
Services Configuration 9 - 21
General
parameters be set: