4.
Preset data: It can be sent with DATA STORE/RECALL in data maintenance mode.
Setting for preset data:
Data in the same format as fixed data of the print parameter shall be set. However, if C/D is
present in the barcode field, calculate C/D and set. When format is registered, record preset.
For one data to be transmitted, SOH + 9 as header and EOT as trailer should be put for all
items.
SOH
9
EOT
Note: Parenthesis shows the number of byte for each term.
Page 6-10
STX
Preset No. (4)
Format No. (2)
Preset data (32)
Preset data (32)
(Up to 29 fields)
Preset data (32)