SATO HT200e Operator's Manual page 111

Stand-alone
Hide thumbs Also See for HT200e:
Table of Contents

Advertisement

SECTION 6: ON LINE
CONFIGURATION FOR DATA TO BE TRANSMITTED
1.
Command for specifying medium
Where print parameter or preset data is sent, for each data to be transmitted, SOH + medium
assignment shall be sent as header and EOT be transmitted as trailer. This sending is not on
a field unit basis, and each command should be put at the head and end as described.
SOH
Medium assignment
"7"
"9"
"H"
"I"
"J"
2.
Print parameter: It can be sent with DATA STORE/RECALL in data maintenance mode.
For one format, data to be transmitted will be enclosed within STX to ETX and sent on a unit
format basis.
SOH
7
STX Format No. (2)
Name of format (10)
Format No. (2) Item name (10) Parameter (46) Fixed data (32)
Format No. (2) Item name (10) Parameter (46) Fixed data (32)
STX
Format No. (2)
Name of format (10)
Format No. (2) Item name (10) Parameter (46) Fixed data (32)
Format No. (2) Item name (10) Parameter (46) Fixed data (32)
Important: The last field shall be set as the field for the number of paper. Parenthesis shows
the number of byte for each term.
Page 6-6
Medium assignment
Data on print parameter for HT200e
Preset data:
The number can voluntarily be established from 0001 to 9999.
Data for table 1:
The number can be assigned from 001 to 200.
Data for table 2:
The number can be assigned from 001 to 200.
Data for table 3:
The number can be assigned from 001 to 500.
Data regulating print position (12)
Name of label (10)
(Up to 30 fields)
Data regulating print position (12)
Name of label (10)
(Up to 30 fields)
Description on data to be transmitted
ETX
ETX EOT