SATO HT200e Operator's Manual page 110

Stand-alone
Hide thumbs Also See for HT200e:
Table of Contents

Advertisement

3.
Transmission of field parameter and field data
Field parameter specifies item name, print position, and font type, from which filed data can
be assigned for data on print.
The parameter and data shall be set on a field unit basis for sending. Up to 30 fields can be
repeatedly specified.
Item name can be designated by 10 bytes.
Parameter can be designated by 46 bytes.
Fixed data can be designated by 32 bytes.
Field
No.
N
N
1
2
3
Field designation
Digit position 1
1: Normal
2: Price
3: Calendar
7: Barcode
SATO HT200e
Item name
4
5
6
7
8
2
0: Normal
1: Table data
0: Normal
1: POP
0: Date
1: Time
0: Human readable
information (HRI) is NOT
available.
1: Human readable
information (HRI) is
available.
Parameter
9
10
1
2
3
Selectable font type
0: X1
1: X2
2: X3
4: OCR-B
0: X1
1: X2
2: X3
5: Character for price
1: POP0: POP1 1: POP2 2: POP3
1: X2
2: X3
0:
NW-7
1: CODE39
3:
EAN13 4: EAN8
6:
CODE128(C Set)
7:
CODE128(A Set, B Set)
SECTION 6: ON LINE
Fixed data
through 46
1
2
3
2: INT2of5
5: UPC-E
3
32
Page 6-5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents