Selecting the Calibrate Laminator tab
The Calibrate Laminator tab is active when the Laminator is automatically detected or when the
Laminator is manually checked (as a Printer Feature on the Configuration tab).
Calibrate button: Sends calibrate Laminator command to Printer. Follow the
instruction on the page for setting up the Printer.
Lamination Module must be warm before sending Calibration option. If not an error will
occur and will trigger the laminator to warm up . Retry the calibration again after
several minutes.
Step
Procedure
Option
1
Select the Calibrate Laminator tab.
a. Remove the Laminate Cartridge
b. Ensure the Laminator Cover is closed.
c. Click on the Calibrate button.
d. Click on the OK button to close the screen.
e. If successful the printer‟s LCD will reset to ready.
Option
NOTE: Calibration of the Ribbon, Film, and Lamination may also be
2
performed from the DISPLAY ICON.
a.
Remove the Laminate Cartridge
b. Ensure the Laminator Cover is closed.
c. Select Lam Calibrate option from the Display.
d. If successful the printer‟s LCD will reset to ready.