Using the Calibrate Ribbon tab

The two buttons for the Calibrate Ribbon tab are described below.
 Calibrate button: Sends the Calibrate Ribbon Command to Printer. Follow the instructions below to
set up the Printer.
 Help button: Launches help specific to this tab.
Step
Procedure
1
Select the Calibrate Ribbon tab.
a. Ensure that the Ribbon is removed from the Ribbon Drawer.
b. Ensure that the Ribbon Cartridge is removed.
c. Ensure the Printer‟s Cover is closed.
d. Click on the Calibrate button. (Note: The Printer will display
CALIBRATE PASSED DTC4000)
e. Click on the OK button (on the driver window) to complete the
procedure.
DTC1000/DTC1000M/DTC4000 Card Printer/Encoder User Guide (L001398, Revision 1.5)