H3C S7500E Series Operation Manual page 1170

S7500e series
Hide thumbs Also See for H3C S7500E Series:
Table of Contents

Advertisement

Operation Manual – Information Center
H3C S7500E Series Ethernet Switches
Configure the output rules
of the system information
Configure the format of
the time stamp
II. Enabling the display of system information on a monitor terminal
After setting to output system information to a monitor terminal, you need to enable the
associated display function in order to display the output information on the monitor
terminal.
Follow these steps to enable the display of system information on a monitor terminal:
Enable the monitoring of
system information on a
monitor terminal
Enable the display of
debugging information on
a monitor terminal
Enable the display of log
information on a monitor
terminal
Enable the display of trap
information on a monitor
terminal
To do...
info-center source
{ module-name | default }
channel
{ channel-number |
channel-name } [ debug
{ level severity | state
state } * | log { level
severity | state state } * |
trap { level severity |
state state } * ] *
info-center timestamp
{ debugging | log | trap }
{ boot | date | none }
To do...
Use the command...
terminal monitor
terminal debugging
terminal logging
terminal trapping
Chapter 1 Information Center Configuration
Use the command...
1-10
Remarks
Optional
Refer to
Table 1-4
for the
default output rules of the
system information.
Optional
By default, the time stamp
format for log, trap and
debugging information is
date.
Remarks
Required
Enabled on the console
and disabled on the
monitor terminal by default.
Required
Disabled by default
Optional
Enabled by default
Optional
Enabled by default