How to set parameters
a) Operating method: Terminal input
Set the operation control mode selection  to .
b) Use the RES terminal for switching. (Instead, other terminals may be used.)
RES: Acceleration/deceleration switching signal
Title
Input terminal selection 3 (RES)

Acceleration/ deceleration pattern
Acceleration/deceleration patterns can be selected individually, using the acceleration/deceleration 1, 2
and 3 parameters.
1) Linear acceleration/deceleration
2) S-pattern acceleration/deceleration 1
3) S-pattern acceleration/deceleration 2
Title
Acceleration/ deceleration 1 pattern

Acceleration/ deceleration 2 pattern

Both the settings of the S-pattern lower-limit and upper-limit adjustment parameters ( and
) are applied to any acceleration/deceleration S-pattern.
⇒ For an explanation of acceleration/deceleration patterns, see section 6.16.1.

6.17 Protection functions

6.17.1 Setting motor electronic thermal protection
 : Motor electronic thermal protection level 1
 : Motor electronic thermal protection level 2
 : Motor 150%-overload time limit
: Motor electronic-thermal protection retention selection
Function
0-72
Function
0: Linear
1: S-pattern 1
2: S-pattern 2
F-57
Adjustment range
acceleration/deceleration
Adjustment range
E6581381
Setting value
5 (the second
mode selection)
6
Default setting
0
0