Toshiba TOSVERT VF-FS1 Instruction Manual page 96

Industrial inverter for 3-phase induction motors
Hide thumbs Also See for TOSVERT VF-FS1:
Table of Contents

Advertisement

If the detection band value + the set frequency is less than the designated frequency
6.1.4
 :Speed reach setting frequency
 :Speed reach detection band
・Function
6
When the output frequency becomes equal to more than f101+f102, ON-signal is generated.After that,
the output frequency becomes equal to less than f101-f102, OFF-signal is generated.
[Parameter setting]
[Parameter setting]
Note: Select the f132 parameter to specify FLA-FLC-FLB terminal output.
Output frequency [Hz]
 + 
 - 
Set frquency speed reach signal
RY-RC terminals
FLA-FLC-FLB terminals
Set frequency speed reach signal:
Inverted
Over set frequency attainment signal
Title
Speed reach setting frequency
f101
Speed reach detection band
f102
Title
Function

Output
terminal
selection 1A
(RY-RC)

0
Function
Adjustment range
0.0- fh (Hz)
0.0- fh (Hz)
Adjustment
range
0-255
66: RCHO (Over set frequency attainment
signal - ON signal), or
67: RCHON (Over set frequency attainment
signal - OFF signal)
F-4
E6581381
Time [s]
ON
OFF
ON
OFF
Default setting
0.0
2.5
Setting value