Toshiba TOSVERT VF-FS1 Instruction Manual page 220

Industrial inverter for 3-phase induction motors
Hide thumbs Also See for TOSVERT VF-FS1:
Table of Contents

Advertisement

• PM motor parameters
Communication
Title
No.
0910

0911

0912

Default settings by inverter rating
Acceleration
Deceleration
Inverter type
, ,
,

VFFS1-2004PM
VFFS1-2007PM
VFFS1-2015PM
VFFS1-2022PM
VFFS1-2037PM
VFFS1-2055PM
VFFS1-2075PM
VFFS1-2110PM
VFFS1-2150PM
VFFS1-2185PM
VFFS1-2220PM
VFFS1-2300PM
VFFS1-4004PL
VFFS1-4007PL
VFFS1-4015PL
VFFS1-4022PL
11
VFFS1-4037PL
VFFS1-4055PL
VFFS1-4075PL
VFFS1-4110PL
VFFS1-4150PL
VFFS1-4185PL
VFFS1-4220PL
VFFS1-4300PL
VFFS1-4370PL
VFFS1-4450PL
VFFS1-4550PL
VFFS1-4750PL
Function
Unit
Step-out detection
%
current level
(A)
Step-out detection
s
time
High-speed torque
-
adjustment
coefficient
Torque
PWM
boost value
carrier
time
1/2
frequency
/

(kHz)
(%)
10
6.0
12.0
10
6.0
12.0
10
6.0
12.0
10
5.0
12.0
10
5.0
12.0
10
4.0
12.0
10
3.0
12.0
10
2.0
12.0
10
2.0
12.0
30
2.0
8.0
30
2.0
8.0
30
2.0
8.0
10
6.0
12.0
10
6.0
12.0
10
6.0
12.0
10
5.0
12.0
10
5.0
12.0
10
4.0
12.0
10
3.0
12.0
10
2.0
12.0
10
2.0
12.0
30
2.0
8.0
30
2.0
8.0
30
2.0
8.0
30
2.0
8.0
30
2.0
8.0
30
2.0
8.0
30
2.0
8.0
Minimum
setting unit
Adjustment range
Panel/Commun
ication
1/1
10-150
0.1/0.1
0.0: No detection
0.1-25.0
0.01/0.01
0.00-650.0
Automatic
Motor
Motor
torgue
rated
no-load
boost
current
current
value



(%)
(A)
(%)
WN/: 2 WP/: 1
6.2
2.0
65
5.8
3.4
60
4.3
6.2
55
4.1
8.9
52
3.4
14.8
48
3.0
21.0
46
2.5
28.2
43
2.3
40.6
41
2.0
54.6
38
2.0
68.0
36
1.8
80.0
34
1.8
108.0
32
6.2
1.0
65
5.8
1.7
60
4.3
3.1
55
4.1
4.5
52
3.4
7.4
48
2.6
10.5
46
2.3
14.1
43
2.2
20.3
41
1.9
27.3
38
1.9
34.0
36
1.8
40.0
34
1.8
54.0
32
1.8
67.0
27
1.7
80.0
26
1.6
98.0
24
1.5
129.0
28
K-14
Default
setting
setting
100
0.0
0.00
Motor
adjustment
Motor rated speed
coefficient
 (min-1)

1680
1400
90
1690
1408
80
1690
1408
70
1680
1400
70
1690
1408
70
1730
1441
70
1730
1441
70
1730
1441
60
1730
1441
50
1750
1458
50
1750
1458
50
1745
1454
50
1680
1400
90
1690
1408
80
1690
1408
70
1680
1400
70
1690
1408
70
1730
1441
70
1730
1441
70
1730
1441
60
1730
1441
50
1750
1458
50
1750
1458
50
1745
1454
50
1750
1458
50
1750
1458
50
1755
1462
40
1775
1479
40
E6581381
User
Reference
6.23
Display unit
selection for
integral
output power

0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
1
1
1
1
1
1
1
1
2
2
2
2

Advertisement

Table of Contents
loading