Toshiba TOSVERT VF-FS1 Instruction Manual page 109

Industrial inverter for 3-phase induction motors
Hide thumbs Also See for TOSVERT VF-FS1:
Table of Contents

Advertisement

[Parameter setting]
Title

Frequency setting mode selection 1
 Frequency priority selection
 Frequency setting mode selection 2
1) External switching (Input terminal function 38 : FCHG enabled)
Frequency priority selection parameter  = 
Switching between the command specified with  and  can be made by entering a command
from a terminal board.
To do so, however, the frequency command forced switching function (input terminal function selection: 38)
needs to be set beforehand to an input terminal board.
If an OFF command is entered to the input terminal board: The command specified with  will be
selected.
If an ON command is entered to the input terminal board: The command specified with  will be
selected.
2) Automatic switching by frequency command
Frequency priority selection parameter  = 
The switching between the command specified with  and  is done automatically according to
the frequency command entered.
If the frequency set with  is above 1Hz: The command specified with  will be selected.
If the frequency set with  is 1Hz or less: The command specified with  will be selected.
Function
1: VIA
2: VIB
3: Operation panel
4: RS485 communication
5: UP/DOWN from external
contact
0:  ( Switchable to 
by the input terminal)
1:  (  for output
frequencies equal to or lower
than 1.0 Hz)
1: VIA
2: VIB
3: Operation panel
4: RS485 communication
5: UP/DOWN from external
contact
F-17
Adjustment range
Default setting
E6581381
1
0
2
6