Toshiba TOSVERT VF-FS1 Instruction Manual page 222

Industrial inverter for 3-phase induction motors
Hide thumbs Also See for TOSVERT VF-FS1:
Table of Contents

Advertisement

Table of input terminal functions 2
Function
No.
43
44
45
46
47
48
49
51
52
53
54
55
56
57
61
62
64
65
66
67
11
68
69
70
71
72
Note: When function 1, 10, 11, 16, 38, 41-47, 51-55, 62 or 64 is assigned to an input terminal board, the input
terminal board is enabled even if the parameter command mode selection  is set at (panel).
Code
CLR
Frequency UP/DOWN cancellation signal input
from external contacts
CLR+RES
Combination of frequency UP/DOWN cancellation
and reset by means of external contacts
EXTN
Inversion of trip stop command from external
device
OH
Thermal trip stop signal input from external device
OHN
Inversion of thermal trip stop command from
external device
SC/LC
Forced switching from remote to local control
HD
Operation holding (stop of 3-wire operation)
CKWH
Display cancellation of the cumulative power
amount (kWh)
FORCE
Forced operation
FIRE
Fire-speed control
STN
Coast stop (gate off)
RESN
Inversion of RES
F+ST
Combination of forward run and standby
R+ST
Combination of reverse run and standby
OCS2
Forced switching of stall prevention level 2
HDRY
Holding of RY-RC terminal output
PRUN
Cancellation (clearing) of operation command from
panel
ICLR
PID control integral value clear
ST+F+SS1
Combination of standby, forward run and preset-
speed command 1
ST+R+SS1
Combination of standby, reverse run and preset-
speed command 1
ST+F+SS2
Combination of standby, forward run and preset-
speed command 2
ST+R+SS2
Combination of standby, reverse run and preset-
speed command 2
ST+F+SS3
Combination of standby, forward run and preset-
speed command 3
ST+R+SS3
Combination of standby, reverse run and preset-
speed command 3
PIDSW
PID forward/reverse switching
Function
OFF→ON: Resetting of UP/DOWN frequency by
ON: Simultaneous input from CLR and RES
OFF:  Trip stop
ON:  Trip stop
OFF:  Trip stop
Enabled when remote control is exercised
ON: Local control (setting of ,  and
)
OFF: Remote control
ON: F (forward run)/R: (reverse run) held, 3-wire
OFF: Slowdown stop
ON: Monitor display cancellation of the cumulative
ON: Forced operation mode in which operation is
OFF: Normal operation
ON: Fire-speed operation ( Forced fire-
OFF: Normal operation
ON: Coast stop (gate off)
ON: Acceptance of reset command
OFF→ ON: Trip reset
ON: Simultaneous input from F and ST
ON: Simultaneous input from R and ST
ON: Enabled at the value of 
OFF: Enabled at the value of 
ON: Once turned on, RY-RC are held on.
OFF: The status of RY-RC changes in real time
0: Operation command canceled (cleared)
1: Operation command retained
ON: PID control integral value always zero
OFF: PID control permitted
ON: Simultaneous input from ST, F and SS1
ON: Simultaneous input from ST, R and SS1
ON: Simultaneous input from ST, F and SS2
ON: Simultaneous input from ST, R and SS2
ON: Simultaneous input from ST, F and SS3
ON: Simultaneous input from ST, R and SS3
ON: Reversing characteristic by  selection
OFF: Characteristic by  selection
K-16
E6581381
Action
means of external contacts
operation
power amount (kWh)
not stopped in the event of the occurrence of
a soft fault ( Forced fire-speed setting
frequncy)
speed setting frequncy)
according to conditions.