Toshiba TOSVERT VF-FS1 Instruction Manual page 33

Industrial inverter for 3-phase induction motors
Hide thumbs Also See for TOSVERT VF-FS1:
Table of Contents

Advertisement

Calorific values of the inverter and the required ventilation
About 5% of the rated power of the inverter will be lost as a result of conversion from AC to DC or from DC to
AC. In order to suppress the rise in temperature inside the cabinet when this loss becomes heat loss, the
interior of the cabinet must be ventilated and cooled.
The amount of forcible air-cooling ventilation required and the necessary heat discharge surface quantity
when operating in a sealed cabinet according to motor capacity are as follows.
1
Note1: The heat loss for the optional external devices (input reactor, radio noise reduction filters, etc.) is not
Note2: Case of 100% Load Continuation operation.
Voltage class
Three-Phase
200V class
Three-Phase
400V class
Panel designing taking into consideration the effects of noise
The inverter generates high frequency noise. When designing the control panel setup, consideration must be
given to that noise. Examples of measures are given below.
• Wire so that the main circuit wires and the control circuit wires are separated. Do not place them in the
same conduit, do not run them parallel, and do not bundle them.
• Provide shielding and twisted wire for control circuit wiring.
included in the calorific values in the table
Operating motor
capacity
Carrier frequency
(kW)
0.4
0.75
1.5
2.2
4.0
5.5
7.5
11
15
18.5
22
30
0.4
0.75
1.5
2.2
4.0
5.5
7.5
11
15
18.5
22
30
37
45
55
75
Calorific Values (w)
cooling ventilation required
Carrier frequency
8kHz
12kHz
-
44
-
63
-
101
-
120
-
193
-
249
-
346
-
459
-
629
698
-
763
-
1085
-
-
45
-
55
-
78
-
103
-
176
-
215
-
291
-
430
-
625
603
-
626
-
847
-
980
-
1257
-
1459
-
1949
-
A-22
E6581381
Amount of forcible air
Heat discharge surface
area required for sealed
3
(m
/min)
storage cabinet(m
0.25
0.88
0.36
1.26
0.58
2.02
0.68
2.4
1.1
3.86
1.42
4.98
1.97
6.92
2.62
9.18
3.59
12.58
3.98
13.96
4.35
15.26
6.18
21.7
0.26
0.9
0.31
1.1
0.44
1.56
0.59
2.06
1.0
3.52
1.23
4.3
1.66
5.82
2.45
8.6
3.56
12.5
3.44
12.06
3.57
12.52
4.83
16.94
5.59
19.60
7.17
25.14
8.32
29.18
11.11
38.98
2
)