Advanced Wan Setup; Figure 237 Menu 2.1: Advanced Wan Setup; Table 156 Advanced Wan Port Setup: At Commands Fields - ZyXEL Communications ZyWall 35 User Manual

Internet security appliance
Hide thumbs Also See for ZyWall 35:
Table of Contents

Advertisement

ZyWALL 35 User's Guide

27.5 Advanced WAN Setup

To edit the advanced setup for the Dial Backup port, move the cursor to the Edit Advanced
Setup field in Menu 2 - WAN Setup, press the [SPACE BAR] to select Yes and then press
[ENTER].

Figure 237 Menu 2.1: Advanced WAN Setup

Menu 2.1 - Advanced WAN Setup
AT Command Strings:
Dial= atdt
Drop= ~~+++~~ath
Answer= ata
Drop DTR When Hang Up= Yes
AT Response Strings:
CLID= NMBR =
Called Id=
Speed= CONNECT
The following table describes fields in this menu.

Table 156 Advanced WAN Port Setup: AT Commands Fields

FIELD
AT Command
Strings:
Dial
Drop
Answer
Drop DTR When
Hang Up
AT Response
Strings:
CLID (Calling Line
Identification)
Called Id
Speed
428
Note: Consult the manual of your WAN device connected to
your Dial Backup port for specific AT commands.
Press ENTER to Confirm or ESC to Cancel:
DESCRIPTION
Enter the AT Command string to make a call.
Enter the AT Command string to drop a call. "~" represents a one second wait,
e.g., "~~~+++~~ath" can be used if your modem has a slow response time.
Enter the AT Command string to answer a call.
Press the [SPACE BAR] to choose either Yes or No. When Yes is selected (the
default), the DTR (Data Terminal Ready) signal is dropped after the "AT
Command String: Drop" is sent out.
Enter the keyword that precedes the CLID (Calling Line Identification) in the AT
response string. This lets the ZyWALL capture the CLID in the AT response
string that comes from the WAN device. CLID is required for CLID
authentication.
Enter the keyword preceding the dialed number.
Enter the keyword preceding the connection speed.
Call Control:
Dial Timeout(sec)= 60
Retry Count= 0
Retry Interval(sec)= N/A
Drop Timeout(sec)= 20
Call Back Delay(sec)= 15
Chapter 27 WAN and Dial Backup Setup