Installing An Intel Management Module (Imm) - Gateway 9515 User Manual

9515 server
Table of Contents

Advertisement

Installing an Intel Management Module
(IMM)
The optional Intel Management Module (IMM) provides enhanced levels of server
functionality over the standard baseboard management controller (BMC). Several
additional features become available with the IMM installed, including memory mirroring
and sparing, redundant hot-swap chassis fans, and the local control panel (LCP).
To install an Intel Management Module (IMM):
1
If Gateway Server Manager (GSM) software is installed in your server, uninstall it prior
to installing the IMM module.
2
Follow the instructions in
sure you turn off the server, then unplug the power cord and all other cables connected
to the server.
3
Follow the instructions in
4
Remove the riser assembly by following the instructions in
the PCI riser assembly" on page
5
Install the nylon standoff into the one corner hole in the IMM module board which
corresponds to one of the holes in the system board (see the illustration on
Important
92
"Preventing static electricity discharge" on page
"Opening the server case" on page
79.
The snap fit ends of the standoff goes into the holes in the IMM
module board. The snap lock ends of the standoff goes into the hole
in the system board.
Snap fit end goes into
IMM board.
Snap lock end goes
into system board.
www.gateway.com
43. Make
44.
"Removing and installing
page
93).