Installing An Intel Management Module (Imm) - Gateway 9415 User Manual

Gateway server user manual
Table of Contents

Advertisement

Installing an Intel Management Module
(IMM)
The optional Intel Management Module (IMM) provides enhanced levels of server
functionality over the standard baseboard management controller (BMC). Several
additional features become available with the IMM installed, including memory mirroring
and sparing, redundant hot-swap chassis fans, and the local control panel (LCP).
To install an Intel Management Module (IMM):
1
If Gateway Server Manager (GSM) software is installed in your server, uninstall it prior
to installing the IMM module.
2
Follow the instructions in
sure that you turn off the server, then unplug the power cord(s) and all other cables
connected to the server.
3
Follow the instructions in
4
Remove the riser assembly by following the instructions in
the PCI riser assembly" on page
5
Install the nylon standoff into the corner hole in the IMM module board which
corresponds to one of the holes in the system board (see the illustration on
Important
86
"Preventing static electricity discharge" on page
"Opening the server case" on page
69.
The snap fit end of the standoff goes into the hole in the IMM module
board. The snap lock end of the standoff goes into the hole in the
system board.
Snap fit end goes into
IMM board.
Snap lock end goes
into system board.
www.gateway.com
41. Make
42.
"Removing and installing
page
87).