Replacing A System Fan - Gateway 9515 User Manual

9515 server
Table of Contents

Advertisement

8
Place the fan module over the chassis standoffs and slide the module to the right until
the blue tab clicks into place.
9
Connect the folded fan module ribbon cable to the fan module (and connect the other
end of the cable to the system board, if it is not already connected).
10
Follow the instructions in

Replacing a system fan

The system fans in this server can be individually replaced. However, there must be at least
four fans installed (in the front four positions) in the fan module for adequate cooling to
take place in the chassis.
The fan module also allows for the installation of four additional, redundant fans, in case
one or more of the primary fans fails. These redundant fans must be installed as a set of
four in the back four positions in the fan module and are installed the same way the
primary fans are installed.
86
"Closing the server case" on page