5.4.1 Replacing a lamp

1. Press
to power down the projector. Wait for the internal cooling fans to stop. Turn the main power
switch OFF. Allow the lamps to cool for an additional 5 minutes before continuing with Step 2.
The projector must be powered OFF when replacing a lamp. To replace the lamp in reserve while the other
lamp is still on (hot-swap), make sure the lamp to be removed is cool.
lamp operation modes to allow the lamp to cool sufficiently before removing.
2.
Remove the cover over the lamp changer. Turn the thumb wheel
Lift the cover off.
3. Loosen the (3) lock screws
4. Using the lamp handle, pull the lamp straight up to remove from the projector.
F
IGURE
5. Dispose of the lamp using approved disposal methods for your area.
NOTE: Lamps containing mercury must be treated as hazardous waste if discarded in large volumes.
5-6
Do not remove a hot lamp.Wait at least 5 minutes after powering down or switching
F
5-2 T
W
IGURE
HUMB
HEEL
(Figure
5-3) on the lamp module held in the reserve position.
5-4 T
HE LAMP HANDLE
(Figure
F
5-3
IGURE
LAMP LOCK SCREWS
F
5-5 R
IGURE
EMOVE THE LAMP
RPMX/RPMSP-D132U & RPMSP-D180U User Manual
5-2) on the cover until it is loose.
020-100245-03 Rev. 1 (11-2010)