3. Press one of the input keys on the remote to select and display the image for the source connected in Step
4.
NOTE: For more information on the keys available on the remote and their function, refer to
Operation.
NOTE: To protect the lamp, the projector enforces a 60 second wait period from the time the projector is
powered down and back up again.
Step 6 Adjusting the projection lens
1. Loosen the adjustment handle (turn thumb wheel) on the lens barrel.
2. When the image is focused, lock adjustments in place by tightening the adjustment handle until just tight.
Step 7 Adjusting image geometry using the 6-axis adjuster
The light engine is mounted to the 6-axis adjuster mechanism which can fine-tune the geometry of a displayed
image by moving and rotating the light engine about the X, Y and Z axes.
For single projectors, adjust the 6-axis adjuster until the displayed image fills the screen and appears without
geometric distortion.
For a multi-projector display wall, use the 6-axis adjuster to closely match the image across multiple screens.
Start in the center of the bottom row and work out and up.
To adjust the 6-axis adjuster:
1. Center the image on screen, by adjusting vertical and/or horizontal position.
2. Zoom the image out (make smaller) until it fits within the borders of the screen.
3. Adjust keystone and tilt.
4. Zoom the image in (make larger) to fill the screen.
5. Repeat above until the image appears correctly.
RPMX/RPMSP-D132U & RPMSP-D180U User Manual
020-100245-03 Rev. 1 (11-2010)
F
IGURE
Lock lens adjustments to prevent unnecessary tampering.
2-9 XGA
LENS ADJUSTMENT
Section 2: Installation and Setup