PARTS REMOVAL AND REPLACEMENT

CONSOLE

1.
Remove the four mounting knobs from the back of the console.
2.
Disconnect the main cable, contact heart rate cables (4600 PT/CL), and
cable (4600/4400
the console off the machine.
3.
Reverse the steps to reinstall the
CONSOLE ADJUSTMENT
1.
Loosen the console bracket wing nut.
2.
Pivot the console up or down to adjust the
console to desired viewing angle and then
tighten the wing nut.
POLV-V AND HTD BELT
THE BELTS MUST BE PROPERLY TENSIONED. A BELT THAT IS TOO TIGHT WILL
CAUSE SLOW AND SLUGGISH OPERATION
CAUSE EXCESSIVE NOISE AN DBELT WEAR.
1.
Remove the bottom cover.
2.
Loosen the adjustment bolt that mounts the alternator to the
slotted alternator brace and the pivot adjusting bolt and nut. Swing the
alternator
down.
Remove the Poly-V belt.
3.
4.
Slide the HTD belt toward you and off the HTD
belt from the
machine.
5.
Reinstall the HTD belt.
Page 50
PT/CL)
from the back of the console.
console.
Pivot up
or down
WARNING
.
A BELT THAT IS TOO LOOSE WILL
pUlley.
Lift
Remove the