Alternator Test; Resistor Test - Stairmaster FreeClimber Systems Owner's Manual

Hide thumbs Also See for FreeClimber Systems:
Table of Contents

Advertisement

ELECTRICAL TROUBLESHOOTING

Alternator Test

5.
Perform the Positive Output to Field test on the
Unplug the battery from the power control board
Remove the white wire from the B+ terminal on the alternator
Remove the brown wire from the field terminal on the alternator
Place a short wire with alligator clips on the B+ term inal and the
field (FLD) terminal of the alternator
Step on the machine for approximately 10 to 15 seconds
If full resistance is achieved during this time, your alternator
has correct current
the
alternator.

Resistor Test

6.
Unplug the load resistor from the power control board and set your
voltmeter to
Ohms.
Place one lead from the voltmeter on each of the
threaded posts on the load
voltmeter does not read 2.5 Ohms (±
7.
If the problem sti II
exists,
800-331
-3578.
Page 40
alternator:
flow.
If no resistance is achieved, replace
resistor.
Replace the load resistor if the
10%).
contact the Customer Service Department at