rSF—OP-03:RS-422/485/ OP-04:RS-232C Functions
Function #
rSF-01
1
Displayed weight
2
Gross weight
3
Net weight
4
Tare
5
Gross weight/net weight/tare
6
Accumulated weight
7
Accumulated count
8
Accumulated weight/accumulated count
rSF -02
1
Stream
2
Auto print
3
manual print
4
Accumulation timing print
5
Command
Set point data + gross value
6
(Output per sampling)
Set point data net value
7
(Output per sampling)
rSF -03
1
600 bps
2
1200 bps
3
2400 bps
4
4800 bps
5
9600 bps
6
19200 bps
rSF -04
0
None
1
Odd
2
Even
rSF -05
7
7 bits
8
8 bits
rSF -06
1
1 bits
2
2 bits
rSF -07
1
<CR>
2
<CR><LF>
rSF -08
1
RS-422
2
RS-485
rSF -09
0
No address capability
01 - 99 With address capability
rSF -10
0
None
1
Outputs data with its code number.
Output data
Data transmitting mode
Baud rate bps
Parity
Character bit length
Stop bit length
Terminator
RS-422/485 switching
Address number
Code number output
Function name
Data format: form A (A&D standard)
See {8-6:Data Transmitting Format}.
Data format: form C (accumulation data format)
See {8-6:Data Transmitting Format}.
Set to 9600 bps or less.
Data format: form H (Weighing Condition
Read-Out Format)
See {8-6:data format}.
This setting is invalid when the RS-232C is used.
Set to "0" in case of the RS-232C.
C-10
Default
1
1
5
2
7
1
2
1
0
0