Operation; Turning The Power On; Basic Operation - AND Explosion Protected Weighing Indicator AD-4403-FP ST Series Instruction Manual

St series weighing indicator for explosion protected platform scale
Table of Contents

Advertisement

3-1 Turning the Power On

• Turning on the power switch inside the case illuminates all the display for 2 seconds, then to normal
display.
• [ON/OFF] turns the display on and off, not the power supply.
• When the power is turned OFF with "O" indicated (OFF mode), "O" will be displayed when turned
ON next time. And when turned off with a weight display (Normal mode), it displays the weight.
• This manual explains the operation based on the normal mode.

3-2 Basic Operation

Action
To set Zero.
To subtract Tare. When Gross weight is 0,
clear the tare weight.
To switch the display from "gross" to "net"
weight and vice versa.
To switch to the OFF mode from the normal
mode.
To recall a set point.

3. OPERATION

[ZERO]
[TARE]
[GROSS/NET]
[ON/OFF]
[UNDER]
[OVER]
[PRESET TARE]
[OP. PRELIM] ( [Lo] )
[ZERO BAND] ( [Lo-Lo] )
[FULL]
[FINAL]
[FREE FALL] ( [Hi] )
[PRELIM]
[CODE]
3-1
Key Operation
( [ZERO BAND] )
( [Hi-Hi] )
( [Go] )
* (Type B)

Advertisement

Table of Contents
loading

Table of Contents