In F—Control Input Functions
Function #
in F-01 - 06
0
No capability
1
Zero
2
Tare
3
Batch start
4
Emergency stop
5
Discharge start
6
Key enable
7
Automatic free fall command
8
Tare clear
9
Accumulation command
10
Cancel previous accumulation
11
Total accumulated weight clear
Clear both total accumulated weight and
12
accumulated weight of the code used now.
13
Clear all the accumulated weight by code.
14
Hold
15
Manual print command
16
Weighing unit select
Function name
Control Input; Capability of pins #1 to #9 of the
control signal terminals inside the case.
Edge-input
Level-input
Edge-input
Level-input
Edge-input
Level-input
Edge-input
Edge-input
C-7
Default
in F-01: 1
in F-02: 2
in F-03: 3
in F-04: 4
in F-05: 5
in F-06: 6