3-5 Editing Accumulation data
Set point editing modes
There are 8 modes for editing set point data.
Mode #
Mode name
[0]
Mode 0
[1]
Mode 1
[2]
Mode 2
[3]
Mode 3
[4]
Mode 4
[5]
Mode 5
[7]
Mode 7
[8]
Mode 8
Mode [6] and [9] are not in use.
General procedures
Press [CODE] [FUNC.] in this order. It shows;
*
Press [ESC] to return to the normal mode.
Select a mode # from the above list with numerical keys.
*
Press [ESC] to return to the normal mode.
Follow the procedures on the next page. See the following {Procedures for each mode}.
Press [ESC] to return to the normal mode.
Retrieves the code number with no set point data setting.
Writes set point data over the set point designated by a code
number.
Clears the set point and accumulation data designated by a code
number.
Clears the accumulation data designated by a code number.
Displays all the set points that have been set.
Writes a tare weight over the preset tare weight designated by a
code number.
Clear all the set point data settings.
Clear all the accumulation data.
1. Enter the set point editing mode.
Main display:
Sub display:
Right LEDs: All the LEDs is on while in the mode.
2. Select the mode required.
3. Follow the procedures of each mode.
4. Escape from the set point editing mode.
Description
"CodE"
"oPErAtE"
3-4
Need help?
Do you have a question about the Explosion Protected Weighing Indicator AD-4403-FP ST Series and is the answer not in the manual?