AND Explosion Protected Weighing Indicator AD-4403-FP ST Series Instruction Manual page 28

St series weighing indicator for explosion protected platform scale
Table of Contents

Advertisement

Mode #
Name
[4]
Mode 4
Input the 2-digit code number of the data to be displayed.
*
Press [+/-] to cancel the input and re-input.
*
Press [ESC] to return to the set point editing mode.
Press [F] [ENTER] to display the set point data designated by the
code number.
Press [F] to jump to a code with no set point data.
*
The type of set point is not changed.
Press [ENTER] several times to select a type of set point. Display
shows;
(Type A for normal batching/ loss-in-weigh/ nozzle controlled
weighing mode)
Final→ Free fall→ Preliminary→ Over limit→ Under limit→ Zero
band→ Full→ Preset tare
(Type B for the check-weighing mode.)
Zero band→Hi-Hi→Hi→Go→Lo→Lo-Lo→ Preset tare
In case of "Preset tare", press [ENTER] to jump to a code with set
point data.
After displaying all the data, the mode returns to the set point editing
mode.
[5]
Mode 5
Input the 2-digit code number of the preset tare weight data to be
overwritten with the tare weight.
*
Press [+/-] to cancel the input and re-input.
*
Press [ESC] to return to the set point editing mode.
Press [ENTER] to overwrite the data. It returns to the set point
editing mode after the action.
[7]
Mode 7
Press [ENTER] for more than 0.3 seconds to clear all the set point
data that have been set. (Accumulation data, weight and counts,
won't be cleared.)
*
Press [ESC] to return to the set point editing mode.
*
Perform Mode 7 and 8 to clear both set point data and accumulation
data.
[8]
Mode 8
Press [ENTER] for more than 0.3 seconds to clear all accumulation
data that has been set.
*
Press [ESC] to return to the set point editing mode.
*
Perform Mode 7 and 8 to clear both set point data and accumulation
data.
Description
Displays all the set points that have been set.
Writes a tare weight over the preset tare weight
designated by a code number.
Clears all the set point data that has been set.
Clears all the accumulation data that has been set.
3-6
Display
"CodE
"
"ALL diSP"
"SET POINT" LED: Blinking
"CodE
"
"tr
CoPy"
"SET POINT" LED: Blinking
"CodE
dt"
"ALL
CLE"
"SET POINT" LED: Blinking
"CodE
tL"
"ALL
CLE"
"TOTAL" LED: Blinking