Display
"Chc
Out"
Turns on a terminal #10 to #19 in this order and displays a relevant terminal-number as shown below.
(This check is performed automatically.)
*
Ignore these displays, "J11 6" , "J11 4" , "J11 2" . They are for factory use.
*
To return to the check item-selecting mode, press [ESC].
Terminal #
10
11
14
15
18
19
"Chc
rS"
Pressing [ENTER] sends 123<CR><LF>(ASCII code) at the condition configured in its function,
rSF-03, rSF-04, rSF-05, or rSF-06 and checks if the same data is returned.
An installed option name is displayed on the sub display. In case of OP-03 (RS-422/485), press
[F] to see either "485" or "422" setting.
*
To return to the check item-selecting mode, press [ESC].
Result of check
Good condition
Something wrong
"Chc
An"
Apply a current in the range of 2mA to 22mA with [FUNC.] (Increase) and [F] (Decrease) and see if the
current value is displayed.
*
To return to the check item-selecting mode, press [ESC].
9-2 Clearing "Zero" and "Tare"
To clear the Zero and Tare stored in the memory, turn on the power while pressing [TARE].
Control output (Terminal #10 to #19)
RS-232C/422/485
Display
"PASS"
No change on display
9-4
Check Item
Display
"tb1-10
1"
"tb1-11
2"
"tb1-14
3"
"tb1-15
4"
"tb1-18
5"
"tb1-19
6"
Analog output