9-3 Initialization
You will lose all the setting data stored in the memory by initializing. The lost data can not be
retrieved.
Initialization swaps all the data stored in the memory in the RAM and the EEPROM with the default
data that factory has configured originally. There are 3 types of initialization depending on items to be
initialized. The item marked with "√" in the table below will be initialized.
Initializing Item
RAM Stores;
Zero
Tare
Set point
Total weight
Total count
√
√
√
Initialization procedures
First make sure that the calibration disable switch (inside the case) is set to the ON position. If not,
initialization will not be performed.
Select the type of initialization and follow the procedure number to initialize.
*
To return to the normal mode in the middle of initializing, press [ESC].
RAM initialization: "init rA"
1
Turn the power on while pressing [SET POINT].
1
Turn the power on while pressing [SET POINT].
Press [F],
Press [CALF] while pressing [ENTER] in the normal mode.
1
Press [ENTER].
Press [F],
Press [ENTER], display blinks to warn against losing data.
If not initialize
Press [ESC] to escape from the initialization mode without performing and return to
2
2
2
the normal mode.
To initialize
Press [ENTER] for 3 seconds to initialize the data. It will initialize the data and returns
to the normal mode.
EEPROM Stores;
Function
Calibration
data
data
√
√
√
RAM & Function initialization: "init Fnc"
All data initialization: "initALL"
Enter the RAM initialization mode
Enter the RAM & Function initialization mode
"init Fnc"
Enter the All data initialization mode
"initALL"
Mode name
RAM initialization
RAM & Function initialization
All data initialization
is displayed.
is displayed.
Initialization
9-5
Initialization Mode
Display in the
initialization mode
"init rA"
"initFnc"
"initAll"
"init rA"
Is displayed.
"init rA"
Is displayed.