Fuser web oiler motor assembly removal
See
"Fuser assembly, web oiler 115V 500W" on page 7-11
page 7-11
for the part number.
1.
Remove the fuser top duct. See
2.
Remove the paper path access door cover right mounting screw (A).
3.
Remove the front right handle cover assembly. See
page
4-9.
4.
Disconnect the web oiler motor assembly cable (A).
5.
Remove the fuser web oiler motor assembly mounting screws and remove the assembly.
or
"Fuser top duct removal" on page
A
"Front right handle cover assembly removal" on
"Fuser assembly, web oiler 220V 500W" on
4-34.
Repair information
5060-00x