900 Rip Software Error - Lexmark 13P0195 - C 750dn Color Laser Printer Service Manual

Service manual
Hide thumbs Also See for 13P0195 - C 750dn Color Laser Printer:
Table of Contents

Advertisement

5060-00x
DB1
Explanation
1C
Paper detected at punch timing sensor too long. Dirty or failed punch timing sensor.
1E
Paper not detected at punch timing sensor within timeout. Jam near input, misdirected
sheet (diverter stuck or misaligned), sensor failure.
1F
Finisher internal software error. Intermittent sensor might cause this error.
20
Unexpected sheet detected at punch timing sensor. Stuck diverter (possibly due to
alignment), damaged sheet, dirty or failed sensor.

900 RIP Software Error

There may be a communication problem (bad cable, network connection, and so on), software issue, or a
hardware problem with the controller board/INA. The communication and software aspects should be checked
first. Determine if the problem is constant or intermittent.
Constant 900 errors
Step
Action and questions
1
Reset the ITU electrical disconnect. Turn the printer off.
Raise and lower the lever above the ITU handle. Do not
remove the ITU assembly itself. Make sure the level is
pressed firmly in place. Turn the printer on.
Does the 900 error display?
2
Disconnect the printer from any external connections.
Turn the power off and remove any parallel, USB, or
network connections. Turn the printer on.
Does the 900 error display?
3
Run the internal test pages. Print one of the internal
test pages from the Utilities Menu. If the printer works
correctly while disconnected, have the user or their
network administrator verify that there are no jobs in
the queue which may be causing the error.
Does the error remain?
4
Turn the printer off. Remove any options from the RIP
or riser card, such as additional memory, hard disk
drives, or option cards.
Does the 900 error persist when the printer is turned
on?
2-88
Service Manual
Yes
No
Go to step 2
Problem resolved
Go to step 4
Go to step 3
Inform the user or
Go to step 4
network
administrator of the
issue.
Go to step 5
Determine which
option is causing
the 900 error.

Advertisement

Table of Contents
loading

This manual is also suitable for:

C750C750nC750dn

Table of Contents